Whole Cell Hdac Enzyme Assay

Lab Reagents

Human IgG antibody Laboratories manufactures the whole cell hdac enzyme assay reagents distributed by Genprice. The Whole Cell Hdac Enzyme Assay reagent is RUO (Research Use Only) to test human serum or cell culture lab samples. To purchase these products, for the MSDS, Data Sheet, protocol, storage conditions/temperature or for the concentration, please contact whole assay. Other Whole products are available in stock. Specificity: Whole Category: Cell Group: Hdac Enzyme

Hdac Enzyme information

Radius 24-Well Cell Migration Assay

CBA-125-5 5 x 24 assays
EUR 2362.8
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

Radius 96-Well Cell Migration Assay

CBA-126 96 assays
EUR 686.4
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

Radius 96-Well Cell Migration Assay

CBA-126-5 5 x 96 assays
EUR 2697.6
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

Radius 384-Well Cell Migration Assay

CBA-127 384 assays
EUR 721.2
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

Radius 384-Well Cell Migration Assay

CBA-127-5 5 x 384 wells
EUR 2802
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

CytoSelect 96-well Cell Transformation Assay

CBA-130 96 assays
EUR 866.4
Description: Our CytoSelect 96-Well Cell Transformation Assay (Soft Agar Colony Formation) is suitable for measuring cell transformation where no downstream analysis is required. Cells are incubated in a semisolid agar medium for 7-8 days. The cells are then solubilized, lysed and detected using the included fluorescent dye in a fluorometric plate reader.

CytoSelect 96-well Cell Transformation Assay

CBA-130-5 5 x 96 assays
EUR 3463.2
Description: Our CytoSelect 96-Well Cell Transformation Assay (Soft Agar Colony Formation) is suitable for measuring cell transformation where no downstream analysis is required. Cells are incubated in a semisolid agar medium for 7-8 days. The cells are then solubilized, lysed and detected using the included fluorescent dye in a fluorometric plate reader.

CytoSelect Cell Viability and Cytotoxicity Assay

CBA-240 96 assays
EUR 470.4
Description: The CytoSelect Cell Viability and Cytotoxicity Assay Kit provides a simple format for monitoring cell viability via metabolic activity. Live cells are detected with either MTT (colorimetric detection) or Calcein AM (fluorometric detection). Dead cells are detected by EthD-1 reagent (fluorometric). All 3 detection reagents are included, along with Saponin (a cell death initiator). Prior to the assay, cells may be treated with compounds or agents that affect cell viability. This kit is suitable for eukaryotic cells, not yeast or bacteria.

CytoSelect Cell Proliferation Assay Reagent (Fluorometric)

CBA-250 10 mL
EUR 490.8
Description: Cell Biolabs? CytoSelect Cell Proliferation Assay Reagent (Fluorometric) provides a fluorometric format for measuring and monitoring cell proliferation. Cells can be plated and then treated with compounds or agents that affect proliferation.  Cells are then incubated with the proliferation reagent.  Upon entering metabolically active live cells, the non-fluorescent proliferation reagent is converted into a bright red fluorescent form. An increase in cell proliferation is accompanied by increased fluorescent signal, while a decrease in cell proliferation (and signal) can indicate the toxic effects of compounds or suboptimal culture conditions.  The assay principles are basic and can be applied to most eukaryotic cell lines, including adherent and non-adherent cells and certain tissues.  This cell proliferation reagent can be used to detect proliferation in bacteria, yeast, fungi, protozoa as well as cultured mammalian and piscine cells. The kit contains sufficient reagents for the evaluation of 960 assays in ten 96-well plates or 192 assays in eight 24-well plates.

CytoSelect Cell Proliferation Assay Reagent (Colorimetric)

CBA-253 10 mL
EUR 490.8
Description: Cell Biolabs? CytoSelect WST-1 Cell Proliferation Assay Reagent provides a colorimetric format for measuring and monitoring cell proliferation.  The 10 mL volume is sufficient for the evaluation of 960 assays in ten 96-well plates or 192 assays in eight 24-well plates.  Cells can be plated and then treated with compounds or agents that affect proliferation.  Cells are then detected with the proliferation reagent, which is converted in live cells from WST-1 to the formazan form in the presence of cellular NADH and an electron mediator. An increase in cell proliferation is accompanied by increased signal, while a decrease in cell proliferation (and signal) can indicate the toxic effects of compounds or suboptimal culture conditions.  The assay principles are basic and can be applied to most eukaryotic cell lines, including adherent and non-adherent cells and certain tissues.  This cell proliferation reagent can be used to detect proliferation in bacteria, yeast, fungi, protozoa as well as cultured mammalian and piscine cells.

Radius 48-Well Cell Migration Assay

CBA-5037 48 assays
EUR 622.8
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

Radius 48-Well Cell Migration Assay

CBA-5037-5 5 x 48 assays
EUR 2454
Description: The Radius Cell Migration Assay provides a unique alternative to conventional cell migration assays using the Boyden chamber. Unlike Boyden chamber assays which may only be analyzed at endpoint, the Radius assay uses a proprietary cell culture plate containing a carefully-defined biocompatible hydrogel (Radius gel) spot centralized at the bottom of each well. When cells are seeded in the well, they will attach everywhere except on the Radius gel, creating a cell-free zone. Following cell seeding the Radius gel is removed, allowing migratory cells to move across the area and close the gap.

CytoSelect Cell Transformation Assay (Cell Recovery Compatible), Colorimetric

CBA-135 96 assays
EUR 985.2
Description: CytoSelect 96-Well Cell Transformation Assays (Cell Recovery Compatible) provide a robust system for detecting transformed cells, screening cell transformation inhibitors, and determining in vitro drug sensitivity. A proprietary modified soft agar matrix allows you to either quantify cells using the included fluorescent dye, or recover the cells for further analysis.

CytoSelect Cell Transformation Assay (Cell Recovery Compatible), Colorimetric

CBA-135-5 5 x 96 assays
EUR 4027.2
Description: CytoSelect 96-Well Cell Transformation Assays (Cell Recovery Compatible) provide a robust system for detecting transformed cells, screening cell transformation inhibitors, and determining in vitro drug sensitivity. A proprietary modified soft agar matrix allows you to either quantify cells using the included fluorescent dye, or recover the cells for further analysis.

CytoSelect Cell Transformation Assay (Cell Recovery Compatible), Fluorometric

CBA-140 96 assays
EUR 1027.2
Description: CytoSelect 96-Well Cell Transformation Assays (Cell Recovery Compatible) provide a robust system for detecting transformed cells, screening cell transformation inhibitors, and determining in vitro drug sensitivity. A proprietary modified soft agar matrix allows you to either quantify cells using the included fluorescent dye, or recover the cells for further analysis.

CytoSelect Cell Transformation Assay (Cell Recovery Compatible), Fluorometric

CBA-140-5 5 x 96 assays
EUR 4179.6
Description: CytoSelect 96-Well Cell Transformation Assays (Cell Recovery Compatible) provide a robust system for detecting transformed cells, screening cell transformation inhibitors, and determining in vitro drug sensitivity. A proprietary modified soft agar matrix allows you to either quantify cells using the included fluorescent dye, or recover the cells for further analysis.

StemTAG Stem Cell Colony Formation Assay (Cell Recovery Compatible)

CBA-325 96 assays
EUR 1027.2
Description: Our StemTAG 96-Well Stem Cell Colony Formation Assay provides a high-throughput method to quantify ES cells in just 7-10 days, and no manual cell counting is required. Once colonies are formed, they may be analyzed in three different ways: 1. Lyse cells, then quantify in a fluorescence plate reader using dye included in the kit; 2. Lyse cells, then quantify alkaline phosphatase activity using reagents provided; or 3. Recover colonies from matrix for further culture or analysis.